Waverunner 

Troubleshooting Drive System errors

 

 

E2    Rear Centering Error.

 

1.     Verify 90 psi out of Compressor.

2.     Verify .6 and .3 mpa at Regulators in Motion Base.

3.     Verify Roll / Inclination Sensor is centered at 80H +/- 9 in input test.

 

 

E3 & E4  Front Up / Down Limit Error.

 

1.     Evacuate Pitch Cylinder and retest.

2.     Manually initialize Drive System.

3.     Go to Pitch Valve Test and verify Up / Down Limit Switches are              

                correct.

           4.  In Pitch Valve Test, actuate Pitch ETR with Throttle to verify it is functioning properly.

           5. In same test, verify function of 4 Port Air Valve with Throttle and Handle.

 

 

E5  Front  Volume Error.

 

          Verify Pitch Pot is over 70H when in down position and under E0H when in up position.

 

 

E6   Low Pressure from Tank.

 

1.     Verify .6 and .3 mpa exactly at Regulators in Motion Base.

2.     Verify there are no air leaks in system.

 

 

E7     Compressor Malfunction. (Japaneese Game only)

 

1.     Verify Compressor is pressurizing Tank.

2.      Verfiy .6 and .3 mpa at Regulators in Motion Base.

3.     Verify there are no air leaks.

            

                Note: If Compressor has trouble starting and game has been running on a circuit with less than 20 amps available to it, the Compressor start circuit is toast. Replace Compressor / Tank with an external one rated at or above 1.5 hp / 4 gallon Tank. Connect air hose to existing watertraps in Motion Base.